Data Center QA / QC Ground-Up Construction Dallas, TX

Forty-five years
building what cannot
afford to fail.

L. Scott Stevens — independent quality assurance and quality control consulting for ground-up data center construction. Air-cooled. Liquid-cooled. Delivered right the first time.

45yrs
In Construction
20+yrs
Data Center Focus
100%
Ground-Up Builds
01 / About

A career spent on the construction side of critical infrastructure.

I am Scott Stevens. For forty-five years I have worked in the construction industry, with the last two decades dedicated to the ground-up delivery of data centers — the mission-critical facilities that now underpin nearly everything.

My practice is quality assurance and quality control, with a specialization in mechanical systems, direct-to-chip liquid cooling implementations, and management of the commissioning process. I exist to make sure the building that gets handed over to the operator is the building that was designed — and that every weld, pour, penetration, and plenum is documented, verified, and defensible.

I have built air-cooled facilities and the newer generation of liquid-cooled facilities. Every project I have touched has been ground-up new construction, with the unique rigor that greenfield work demands.

02 / Services

What I do on your project.

01 —

QA / QC Program Development

Building the quality framework that matches your project: inspection and test plans, hold points, acceptance criteria, documentation standards, and reporting cadence calibrated to data center work.

02 —

Field Inspection & Verification

Boots-on-the-site verification that the work installed matches the drawings, specifications, and manufacturer requirements — from slab and structure through MEP rough-in to final commissioning readiness.

03 —

Nonconformance Management

Identifying deficiencies early, tracking them through disposition, and verifying close-out. Issues caught in framing cost a fraction of what they cost after the raised floor goes in.

04 —

Submittal & Documentation Review

Review of submittals, ITPs, weld logs, concrete placement records, and turnover packages against specification and code — so the record that closes the project actually reflects what was built.

05 —

Owner's Representation

Serving as the owner's technical set of eyes on the general contractor and trades — independent, experienced, and focused entirely on the owner's standard of delivery.

06 —

Commissioning Management

Managing the commissioning process from planning through close-out — coordinating trades, the Cx agent, and the owner; driving hold-point readiness; and ensuring systems are installation-complete, properly documented, and ready to be energized, filled, and functionally tested.

03 / Expertise

Two cooling paradigms. One discipline.

{ SYS — 01 }
Traditional

Air-cooled

Legacy and modern air-cooled facilities — CRAC / CRAH systems, hot and cold aisle containment, raised floor and overhead distribution, perimeter and row-based approaches. Decades of experience verifying the thermal envelope is built as designed.

{ SYS — 02 }
Specialty — AI / HPC Era

Liquid-cooled

The generation of facilities built for densities air cannot handle. My focus is direct-to-chip implementations — the piping, CDUs, manifolds, leak detection, and installation tolerances that D2C systems demand, alongside rear-door heat exchanger and immersion-ready designs.

Ground-up.

Every data center I have worked has been new construction from the ground up. Greenfield work has its own pace, its own sequencing, and its own failure modes — and I have spent twenty years learning all of them.

04 / Contact

Let's talk about your build.

— Email
scott@lsstevens.com
— Based In
Dallas, Texas
— Service Area
Central Texas